Hydraulic Fuses
AD 98-06-10 requires the functional checking of the hydraulic fuses every three years or 1200 hours, which ever comes first. It means ALL THREE fuses, not just the indicator fuse. We are finding the sign-off for the AD just referencing the indicator fuse. Also, if you read the brake bleeding instructions in the manual, you will find that the fuse is required to be checked EACH time a brake is replaced and bled.